Overview
The MCM2600 series multi channel power meter has the basic measuring function of Voltage, Current, Frequency, Total power factor, Active power, Reactive power, Apparent power, Active energy, Reactive energy, and 2-31th Individual harmonic. Besides, there are many optional functions such as Voltage harmonic distortion, current harmonic distortion, Time of Use, Voltage imbalance, current imbalance, max demand, voltage deviation, and SOE record so you can choose as your needs. The dimensions of the multi-channel power meter are a length of 228mm, a width of 65mm, and a height of 120mm.
Feature of MCM2600 Multi-channel Power Meter
- 35mm standard din-rail installation
- 13M width with a 1.6” dot matrix LCD screen
- 0.5 class high-precision performance
- Multiple digital energy meter alternative
- 6 channels or 18 channels circuit metering
- Measurement accuracy class 0.5
- Current measuring: 1A or 5A
- Power supply: 85-265VAC/DC
- RS-485 Modbus/RTU Communication
- Optional 6 channels Digital Input (DI) or 2 channels Digital Output (DO)
- Optional advanced electrical parameter
- Optional record and read multi- tariffs ratio, Up to 3 months (TOU record)
- Optional max 99 lists SOE record
- Improving reliability and reducing maintenance costs
- Accept customization design
Selectable Models
|
MCM2603 |
MCM2601 |
MCM2403 |
MCM2401 |
MCM1000 |
MCM400 |
METERING FEATURES |
Voltage (P-P, P-N) |
● |
● |
● |
● |
● |
● |
Current (P-N) |
● |
● |
● |
● |
● |
● |
Frequency |
● |
● |
● |
● |
● |
● |
Total Power factor |
● |
● |
● |
● |
● |
● |
Active power |
● |
● |
● |
● |
● |
● |
Reactive power |
● |
● |
● |
● |
● |
● |
Apparent power |
● |
● |
● |
● |
● |
● |
Active energy consumed |
● |
● |
● |
● |
● |
● |
Active energy generated |
● |
● |
● |
● |
● |
● |
Reactive energy consumed |
● |
● |
● |
● |
● |
● |
Reactive energy generated |
● |
● |
● |
● |
● |
● |
Voltage harmonic distortion (THD) |
○ |
○ |
● |
● |
– |
● |
Current harmonic distortion (THD) |
○ |
○ |
● |
● |
– |
● |
Individial harmonic (1) |
○ |
○ |
● |
● |
– |
● |
Time of Use (TOU) |
○ |
○ |
– |
– |
– |
– |
Current / Voltage unbalance |
○ |
○ |
○ |
○ |
– |
○ |
Max Demand |
○ |
○ |
○ |
○ |
– |
○ |
Voltage deviation |
○ |
○ |
○ |
○ |
– |
○ |
Sequence of Event record (SOE) |
○ |
○ |
– |
– |
– |
– |
MEASUREMENT SIGNAL ACCESS |
1A & 5A |
● |
○ |
– |
– |
● |
– |
100mA |
○ |
● |
● |
● |
– |
● |
333mV |
○ |
○ |
○ |
○ |
– |
○ |
L-L 480V, three phase |
● |
– |
● |
– |
● |
● |
L-N 300V, single phase |
– |
● |
– |
● |
○ |
○ |
4 metering channels (3P) |
– |
– |
● |
– |
– |
● |
6 metering channels (3P) |
● |
– |
– |
– |
● |
– |
12 metering channels (1P2W) |
– |
– |
– |
● |
– |
○ |
18 metering channels (1P2W) |
– |
● |
– |
– |
○ |
– |
HUMAN-MACHINE INTERFACE |
72*72 external display unit |
– |
– |
– |
– |
● |
– |
On board 1.6” dot matrix LCD |
● |
● |
● |
● |
– |
● |
COMMUNICATIONS AND I/O PORT |
RS-485 |
● |
● |
● |
● |
● |
● |
Ethernet 10/100MB |
– |
– |
○ |
○ |
– |
– |
Modbus RTU |
● |
● |
● |
● |
● |
● |
Profubus |
○ |
○ |
○ |
○ |
○ |
○ |
6*Digital inputs |
○ |
○ |
– |
– |
○ |
– |
2*Digital outputs (2) |
○ |
○ |
● |
● |
○ |
– |
● With this function ○ Optional function — Without this function
(1) MCM2603/2601 multi channel energy meter detect 2~31 , MCM2403/2401 detect 2~15.
(2) MCM2603/2601 and MCM1000 sub meter is a signal logic alarm output, 2 relays independent of logic and hardware; MCM2403/2401 with 5 virtual alarms and SPDT relays.
Other notes on multi channel energy monitor:
Max Demand value default calculated by 15min Sliding window method, if need Block Interval please tell us before order. Choose Ethernet port protocol default use MODBUS-TCP.