MCM283R 8-circuit Energy Monitoring Systems for Commercial Buildings

MCM283R 8-circuit Energy Monitoring Systems for Commercial Buildings

The MCM283R energy monitoring systems for commercial buildings is built with 8 main ciruits. It measures up to 8 three-phase circuits or 24 single-phase circuits for real-time metering. Different phase can be connected with each other to measuring different electrical circuits. In other words, it is ideal for commercial complexes billing on individual phase.

In addition, this commercial energy monitoring system is built in RS485, RJ45 interface, you also can choose other interface such as WiFI, Ethernet, Zigbee, 4G, etc. The MCM283R commercial energy meter is equiped with 7.62mm voltage curret power terminals for simplible installation, and complies with the CATIII-300V safety voltage level and the 4kV withstand voltage capability.

The MCM283R energy monitoring systems for commercial buildings is built with 8 main ciruits. It measures up to 8 three-phase circuits or 24 single-phase circuits for real-time metering. Different phase can be connected with each other to measuring different electrical circuits. In other words, it is ideal for commercial complexes billing on individual phase.

In addition, this commercial energy monitoring system is built in RS485, RJ45 interface, you also can choose other interface such as WiFI, Ethernet, Zigbee, 4G, etc. The MCM283R commercial energy meter is equiped with 7.62mm voltage curret power terminals for simplible installation, and complies with the CATIII-300V safety voltage level and the 4kV withstand voltage capability.

MCM283R Features

Compact terminals of RJ45 RS485 DI & Pulse Ouput
The MCM283R is equiped with RJ45, RS485, 18 DI, Pulse output, etc. The RJ45 interface is a common network interface that can be used for large current or high-precision current transmission. This RJ45 current interface has a simple structure and is easy to connect. It makes the MCM283R commercial energy monitoring meter comparible with 100mA CT. Moreover, the DI can be used as pulse input port.
mcm283R multi-circuit Energy Metering for Commercial Buildings compact interface
High Accuracy for Revenue meter energy meter
High Accuracy Revenue meter for Commercial buildings
The MCM283R business electricity meters measure and verfiy commerical bills with revenue-grade accuracy: ANSI C12.20 Class 0.5 & IEC62053-22 Class 0.5s. It is able to bill up to 8 individual three-phase clients or 24 single-phase clients or various combinations in between accuracily. The time-of-Use billing and logging energy chages per day to get accuracy data. Moreover, to ensure the data be accurate, our enclousures of business energy meter is anti-tamper design.
Compatible with CTs, PTs & Rogowski coil
MCM283R commercial power monitoring devices can be connected with CTs, PTs, and Rogowsi coil CT. For example, Any types of 80mA, 100mA, or 333mV Rogowski Coil current transformer can simply connect with the MCM283R commercial energy meter. You also can use 100mA, 1A, 5A current transformer with this commercial energy monitoring devices.
commercial energy monitoring system withoptional ct
MCM283R multi-channel commercial power monitoring meter
Up to 8 or 24 Multi-load Metering
This energy monitoring systems for commercial buildings can measure up to 8 three phase loads, 24 single-phase loads, or various combinations of the two. Take individual phase kwh measurement as an example, the MCM283R measures 3 phase 8 channels or single phase 24 channels at the same tiem to provides user flexibility of kwh measurement.

Specification

Power Supply AC / DC 80-265V, 45-65Hz
Burned < 6VA
Current Measurement …/ 100mA or …/ 333mV
Burned < 0.1W
Voltage Measurement Direct measurement 30~450V ac (L-L)
Burned < 0.1W
Frequency Measurement 45~65Hz
Accuracy U / I / P / Q – 0.5% (Optional 0.2%)
Frequency – 0.1%
Active Energy – 1.0 class
Reactive Energy – 2.0 class
Communication Port RS485 (2/3 wires half duplex)
Modbus RTU mode
Dielectric Strength 4kV / AC RMS

Application

This MCM283R commercial energy monitoring is widely used for commerical complex, commerical mall, hotels buildings, office buildings, apartment, condominums, hostpital services, public services, tenant submetering billing, branch circuit moitoring, energy management systems, data centers and LEED projects.
MCM283R energy monitoring systems for commercial buildings

  • Manufacturing plants, industrial parks and processing workshops;
  • Residential communities, apartment buildings and single-family homes;
  • Schools, hospitals and government buildings;
  • Transportation infrastructure, airports, train stations and subway stations;
  • Data centers such as server rooms, network operation centers.

Dimension

dimension of mcm283T multi-circuit energy meter
MCM283R mulit-circuit commercial power meter dimension